NES-150-15,NES-150-24,NES-150-48,NES-150-3.3,NES-150-5,NES-150-7.5,NES-150-9,NES-150-12,NES开关电源系列
特性:
● 交流输入范围通过开关切换
●保护种类:短路/过负载/过电压
●自然风冷
●自然风冷
●LED电源指示
●100%满载老化测试
●高效,寿命长,高可靠
●2年保固
电气规格:
|
型号
|
NES-150-3.3
|
NES-100-5
|
NES-150-7.5
|
NES-150-9
|
NES-150-12
|
NES-150-15
|
NES-150-4-24
|
NES-150-48
|
|
| 输出 |
直流电压
|
3.3V
|
5V
|
7.5V
|
9V
|
12V
|
15V
|
24V
|
48V
|
|
额定电流
|
30A
|
26A
|
20A
|
16.7A
|
12.5A
|
10A
|
6.5A
|
3.3A
|
|
|
电流范围
|
0-30A
|
0-26A
|
0-20A
|
0-16.7A
|
0-12.5A
|
0-10A
|
0-6.5A
|
0-3.3A
|
|
|
额定功率
|
99W
|
130W
|
150W
|
150W
|
150W
|
150W
|
156W
|
158.4W
|
|
|
纹波与噪声
|
80mVp-p
|
80mVp-p
|
120mVp-p
|
120mVp-p
|
120mVp-p
|
120mVp-p
|
120mVp-p
|
200mVp-p
|
|
|
电压调整范围
|
3.2-3.5V
|
4.75-5.5V
|
7.13-8.3V
|
8.55-9.9V
|
11.4-13.2V
|
14.25-16.5V
|
22.8-26.4V
|
45.6-52.8V
|
|
|
电压精度
|
±3.0%
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
|
线性调整率
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
|
负载调整率
|
±2.0%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
|
启动,上升时间
|
800ms,20ms/230VAC 1200ms,30ms/115VAC(满载时)
|
||||||||
|
保持时间
|
24ms/230VAC 20ms/115VAC (满载时)
|
||||||||
|
I输入
|
电压范围
|
90-132VAC or 254-373VAC or 180-264VAC
|
|||||||
|
频率范围
|
47-63Hz
|
||||||||
|
效率
|
73%
|
78% | 80% | 83% | 83% | 83% | 86% | 86% | |
|
交流电流
|
3A/115VAC 2A/230VAC
|
||||||||
|
浪涌电流
|
冷启动: 45A
|
||||||||
|
漏电流
|
<2mA/240VAC
|
||||||||
|
保护
|
过负载
|
额定输出功率的110%-150%
|
|||||||
|
保护模式:打嗝模式,负载异常条件移除后可自动恢复
|
|||||||||
|
过电压
|
3.8-4.25V
|
5.75-6.75V | 8.6-10.1v | 10.4-12.2V | 13.8-16.2V | 17.25-20.25V | 27.6-32.4V | 55.2-64.8 | |
|
保护模式:关闭输出,电源重启后可恢复正常输出
|
|||||||||
|
环境
|
工作温度
|
-20℃∼+60℃ (请参考负载减额曲线)
|
|||||||
|
工作湿度
|
20℃∼90℃RH (无冷凝)
|
||||||||
|
储存温度,湿度
|
-40℃∼+85℃;10%∼95%RH
|
||||||||
|
温度系数
|
±0.03%/℃(0-45℃)
|
||||||||
|
耐振动
|
10∼500Hz,2G 10分钟./周期, X,Y,Z 轴各60分钟
|
||||||||
|
安规和电磁兼容
|
安全规范
|
UL60950-1,CB(EN60950)-1, pass GB4943
|
|||||||
|
耐压
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
||||||||
|
绝缘阻抗
|
I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC 70%RH
|
||||||||
|
电磁干扰
|
EN55022(CISPR22) Class B, GB9254 认证通过
|
||||||||
|
谐波电流
|
EN61000-3-2,-3
|
||||||||
|
电磁耐受
|
EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-1
|
||||||||
|
其他
|
MTBF
|
≥433.3Khrs, MIL-HDBK-217F(25℃)
|
|||||||
|
尺寸
|
199*98*38mm(L*W*H)
|
||||||||
|
包装
|
0.7k.g;20pcs,15k.g/0.72CUFT
|
||||||||
|
备注
|
1. 如未特别说明,所有规格参数的在输入为230VAC,额定负载,25℃环境温度下进行量测.
2. 纹波和噪声测量方法:使用一条12双绞线,到时终端要并联0.1uF&uF的电容
3. 精度:包含设定误差,线性调整率和负载调整率.
4. 线性调整率测量方法:在额定负载下,从低电压到高电压测试.
5. 负载调整率测量方法:从0%到100%额定负载
7. 电源应视为系统内元件的一部分,总结终端设备进行电磁兼容相关确认
6. 在电流范围内每组输出均正常,但是总功率不便超过额定输出功率. |
||||||||